Quick Tour - Pace ST 115 Operation & Maintenance Manual

Table of Contents

Advertisement

Quick Tour

1. Ensure that the Set-Up procedure has been performed; including the
Heater Burn In procedure. Check for the following:
a) Handpiece connection to the power source.
b) Proper tip installed in handpiece.
c) Power cord connection between house AC supply receptacle and the
power source.
2. Turn the Power Switch "On" ("I").
3. Press the Scroll Up (▲) Key. The Set Temperature is now displayed. If no
other Key is pressed within 5 seconds, the system will revert to normal
operation. Allow time for the system to change back.
4. Press the Scroll Up (▲) Key. The Set Temperature is now displayed;
immediately perform step 5.
5. Adjust the Set Temperature in the following manner:
a) Press and release the Scroll Up (▲) Key to increase Tip Temperature in
increments. Press and release the Scroll Down (▼) Key to decrease
Tip Temperature. Observe the display as the Set Temperature
increases in increments of 1°.
If a Password has been previously programmed into the system, "EP0" will appear on
the LED Display at this point. When this message appears, the operator must enter
the correct 5 key Password before adjusting the temperature. Refer to "Password"
in the "Operation" portion of this manual.
b) Adjust the temperature by pressing and holding Scroll Up (▲) Key.
Observe the display as the Set Temperature increases first in
increments of 1° and then in increments of 10°. Release the key.
c) Using the Scroll Keys, adjust the temperature to any standard
operating temperature used by your company.
The Set Temperature can only be within the set temperature limits. If a limit (upper or
lower) is reached, the lower limit would display "OFF"; the upper limit would not allow
the Set Temperature to exceed that limit. Temperature limits can be adjusted in the Set-
Up Mode
NOTE
NOTE
Operation
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents