10.3.8. Step 8: Adjusting the Endstops
Ensure that the gate is in the fully closed position.
Slightly loosen the Torx screws on the back endstop and adjust the endstop so that it sits up
against the pivot bracket of the operator. Tighten the Torx screws in this position.
If the gate has mechanical endstops in the closed position there is no need to
adjust the nearest endstop on the operator.
Loosen the Torx screws
With the unit still in the override condition, move the gate leaf into the required open
position and adjust the front endstop in the same way. Once the endstop has been adjusted,
close the gate leaf, re-engage the unit and remove the keys. The unit is now ready to be
connected to the controller.
The operator should never be run manually directly off a battery!
Doing so and driving the operator into in an endstop will result in
serious damage being sustained by the worm drive
Never lubricate the worm drive
FIGURE 55. ADJUST ENDSTOPS
page 52
Pivot Bracket
Move the endstop and
tighten the Torx screws