CENTURION SYSTEMS VERT-X Mechanical Installation Manual page 41

Hide thumbs Also See for VERT-X:
Table of Contents

Advertisement

Use the following installation tables to determine the best geometry for the installation.
VERT-X Outward Opening Geometry Tables:
90º Outward Opening Gate
E-Value
>80mm
>82.5mm
>82.5mm
1. Optimum Installation
100º Outward Opening Gate
E-Value
>85mm
>85mm
1. Optimum Installation
Values- A, B, & C are measured from the gate hinge point.
Value- D is measured from the gate hinge point centre line.
Value-E is measured from the gate face to the Gate Bracket centre point.
With this type of operator, it is critical to choose the correct installation
position from the installation tables to ensure that the tip of the
operator does not interfere with the gate during operation.
www.CentSys.com
A-Value
B-Value
140mm
160mm
150mm
150mm
160mm
140mm
1
A-Value
B-Value
155mm
140mm
160mm
135mm
1
C-Value
618mm
628mm
638mm
1
C-Value
633mm
630mm
1
page 41
D-Value
115mm
115mm
115mm
1
1
TABLE 8
D-Value
110mm
110 - 115mm
1
TABLE 9