Administer the data module
Type add data-module extension and press
1
The Data Module screen appears. Use this screen to administer the data module that is
associated with the TN2501AP ethernet port.
add data-module 30006
Data Extension: 30006
Type: ethernet
Port: 1b0333
Link: 5
Network uses 1's for Broadcast Addresses? y
Set the Type field to ethernet.
2
Set the Port field to correspond to the circuit pack location.
3
The port number (final two digits) is always 33 for the TN2501AP circuit pack.
4
Set the Link field to an unassigned or next-available link number.
5
Set the Network uses 1's for Broadcast Address field according to the your network
requirements.
6
Type a unique name in the Name field.
7
Press
to save your changes.
En te r
Administer IP routing (if used)
Type add ip-route and press
1
2
Administer IP routes to the TN2501AP circuit pack.
3
Press
to effect the changes.
En te r
Test the IP connections
Click Start > Run to open the Run dialog box.
1
Type command and press
2
Type ping <ipaddress>, where <ipaddress> is a known computer on the network and
3
press
to verify connectivity.
Enter
Using ASA, type status link to test the new IP connections that you have administered.
4

Avaya R300 Remote Office Communicator

For information on the Avaya R300 Remote Office Communicator, refer to the documentation
that comes with the R300 equipment.
E nte r
DATA MODULE
Name: VAL#2 Data Module
.
E nte r
to open an MS-DOS window.
Enter
May 2002
Installing the S8700 Multi-Connect