Connect DC Power to the Media Gateways

1
2
3
4
Connect small battery holdover cable (or temperature sensor cable from large battery
cabinet) to J20
Carrier Circuit Breakers
Ground Terminal Block
Connect -48 VDC Return - 1 AWG (50 mm
Connect -48 VDC - 1 AWG (50 mm
2
1 AWG (50 mm
) 50 ft. (15.2 m) cable to large battery cabinet. For cables greater than 50
ft. (15.2 m), contact your Avaya representative.
Ground Terminal Block
To AC load center or approved single-point ground block
Be sure the main circuit breaker is OFF.
Measure and cut 2 pieces of 1 AWG (#70) (44 mm
DC power cabinet to the first media gateway.
At the DC power cabinet, connect the -48 volt DC wire to the DC OUTPUT circuit
breaker. See
''Typical Power and Ground for a DC power cabinet'' on page
the -48 volt RTN (return) wire to the ground discharge bar.
Route the wires out of the cabinet, through the hole in the lower rear cover, and to the
first media gateway.
1
5
6
2
) red cable here.
2
) black cable
2
) wire long enough to reach from the
May 2002
2
3
7
4
60. Connect
8