Starting up the fill-level control sensor
General
The fill-level control sensor releases a signal as soon as the fill level in the parting agent
container falls below a defined level.
Operating con-
trols and displays
on the sensor
Performing empty
adjustment
(2)
(1)
(3)
20 mm (0.79 in.)
2 - 6 s
No.
Function
(1)
'OUT OFF' key
to program the sensor
(2)
'OUT ON' key
to program the sensor
(3)
LED
shows the operating mode of the
sensor
-
LED on/flashing: Sensor active
-
LED off/ not flashing: Sensor inac-
tive
Drain the parting agent container until
1
the parting agent is at least 20 mm
(0.787 in.) below the sensor
Connect the sensor to the power sup-
2
ply
Hold the 'OUT OFF' key for at least 2
3
seconds, maximum 6 seconds
-
The LED on the sensor flashes
slowly
-
after releasing the 'OUT OFF' key,
the LED turns off once again - the
sensor has detected a low fluid le-
vel
45