MAX VOLTAGE--------press ENTER key, input the maximum voltage then press ENTER
2.
MIN VOLTAGE ---------press ENTER key, input the minimum voltage then press ENTER.
3.
MAX CURRENT--------press ENTER key, input the maximum current then press ENTER.
4.
MIN CURREN-----------press ENTER key, input the minimum current then press ENTER.
5.
MAX RESISTANCE----press ENTER key, input the maximum resista nce then press ENTER
6.
MIN RESISTANCE-----press ENTER key, input the minimum resistance then press ENTER
7.
MAX POWER----------- press ENTER key, input the maximum power then press ENTER
8.
MIN POWER------------ press ENTER key, input the minimum power then press ENTER
11. CAL. PARAM.-----press ENTER key, input the MEASURE LOW/ MEASURE HI GH / TRAN. OFFSET, then
press ENTER.
1: LOW MEAS POINT 2: HIGH MEAS POINT 3: TRANS OFFSET
1: LOW MEASURE POINT--press ENTER key, set the low measure count value then press ENTER.
2: HIGH MEASURE POINT-press ENTER key, set the high measure count value then press ENTER.
3: TRANSIENT OFFSET---- press ENTER key, set the transient offset count then press ENTER.
12. OSCILLATE-------press ENTER key, select the OSC. CONTROL/ OSC. DELAY, then press ENTER.
13. BOOT INPUT--------press ENTER key, use  to select ON / OFF then press ENTER.
B: Profile Menu
- press ENTER key:
* Use   to select the next menu setting then press ENTER key to enter the selected menu.
* Use CLEAR key to back space or to correct the wrong value.
1: RECALL 2: SAVE  3: RESET
RECALL----------press ENTER key, use  to select the profile 0/1/2/3 then press ENTER to recall.
1.
SAVE----------press ENTER key, use  to select the profile 0/1/2/3 then press ENTER to save.
2.
3.
RESET---------press ENTER key, then press ENTER to reset.
C: Display Menu
- press ENTER key:
* Use   to select the next menu setting then press ENTER key to enter the selected menu.
* Use CLEAR key to back space or to correct the wrong value.
1: Meter Mode 2: 'C' Value
1. METER MODE---press ENTER key, use  to select display mode (V+I, V+P, V+C, V+R, I+P, I+C, I+R,
R+P, R+C, P+C, V+T, I+T, R+T, P+T, C+T) then press ENTER.
2. 'C' Value------press ENTER key, then input the C value in Ampere.
D: System Menu
- press ENTER key:
* Use   to select the next menu setting then press ENTER key to enter the selected menu.
* Use CLEAR key to back space or to correct the wrong value.
1: GPIB ADDRESS 2: RS-232 SPEED  3: SYNTAX MODE 4: EOS CODE  5: BUZZER
 6: PANEL LOCK 7: ETHERNET
1. GPIB ADDRESS--press ENTER key, use  to set the GPIB address ( 0 – 31 ) then press ENTER.
2. RS-232 SPEED----press ENTER key, use  to set the BAUD RATE ( 2400 – 115200 ) then press ENTER.