Ac Input Power Connection; Ac Input Connector And Voltage Selection - Ametek Amrel PLA Series Operation Manual

Programmable dc electronic load
Table of Contents

Advertisement

Model Type
PLW6K
PLW9K
PLW12K
PLW18K
PLW24K
PLW36K
PLW48K - Slave
PLW48K - Master
PLW60K - Slave
PLW60K - Master
PLA-2U
PLA-3U
PLA-4U
PLA-6U
PLA-8U-Master
PLA-8U-Slave
TABLE 2.2 – FUSE REPLACEMENT SPECIFICATIONS

AC INPUT POWER CONNECTION

WARNING
Disconnect AC power from the instrument before removing the cover. Even with the front panel power switch in
the OFF position, live line voltages are exposed when the cover is removed and the AC cord is attached. Repairs
must be made by experienced service technicians only.
NOTE: REMOVING THE TOP COVER OR DISASSEMBLING THE UNIT WILL VOID THE WARRANTY.
WARNING
JJJJJJ
There is a potential shock hazard if the electronic load chassis a nd cover are not connected to a n electrical ground
via the safety ground in the AC input connector. Ensure that the electronic load is connected to a grounded AC
outlet with the recommended AC input connector configured for the available line voltage.

AC INPUT CONNECTOR AND VOLTAGE SELECTION

CAUTION
To prevent damage to the electronic load, turn off AC power to the unit before changing from one AC input
voltage range to another. Example 115Vac to 230Vac.
eLoad series has an auto range selection function. This function allows you to connect to either low or high AC input
voltage without making any adjustment to the unit.
M470039-01 REV-F
Fuse Rating
Specification
2.5A/250V
Slow Blow
4A/250V
Slow Blow
4A/250V
Slow Blow
4A/250V
Slow Blow
6.3A/250V
Slow Blow
6.3A/250V
Slow Blow
10A/250V
Slow Blow
6.3A/250V
Slow Blow
10A/250V
Slow Blow
6.3A/250V
Slow Blow
2.5A/250V
Slow Blow
4A/250V
Slow Blow
6.3A/250V
Slow Blow
8A/250V
Slow Blow
10A/250V
Slow Blow
6.3A/250V
Slow Blow
Location
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
External Fuse (Beneath the AC receptacle)
Page 47