CALIBRATION CONFIGURATION
There are two configurations for the calibration of the electronic load. One is for measuring voltage and the
other for measuring current.
0.01
CURRENT
SHUNT
FIGURE 5.1 – CALIBRATION SETUP CONFIGURATION
CALIBRATION PARAMETERS
The following are the parameters that are calibrated.
•
CV main level programming.
•
CC low range main level programming.
•
CC high range main level programming.
•
CR low range main level programming.
•
CR middle range main level programming.
•
CR high range main level programming.
•
CP low range main level programming.
•
CP high range main level programming.
•
CV transient level programming.
•
CC low range transient level programming.
•
CC high range transient level programming.
•
CR low range transient level programming.
•
CR middle range transient level programm ing.
•
CR high range transient level programming.
•
CP low range transient level programming.
•
CP high range transient level programming.
•
CV readback.
•
CC low range readback.
•
CC high range readback.
M470039-01 REV-F
PLW
INPUT
+
-
+
POWER SUPPLY
+
−
−
+
−
DMM
)
(VOLTAGE
DMM
)
(CURRENT
Page 105