MENU FUNCTION

The MENU function allows the user to set the d ifferent system configurations such as GPIB, Stepping, Max/Min setting,
Protection, and Calibration. The vast array of features and configurations allow the eLoad to accommodate different
situations or testing configurations. The Local/Menu function is the start of the tree structure, which enables the user to
branch.
Press MENU key:
* Use  to select the next menu setting then press ENTER key to enter the selected menu.
* Use CLEAR key to back space or to correct the wrong value.
A: LOAD CONTROL  B: PROFILE  C: DISPLAY  D: SYSTEM 
E: AUTHENTICATE
A: Load Control Menu
* Turn the encoder   to select the next menu setting then press ENTER key to enter the selected menu.
* Use CLEAR key to back space or to correct the wrong value.
1: STEP PARAM. 2: MEASURE SENSE  3: PORT 0 4: EXT. CONTROL  5: SHORT
CONTROL  6: CROSS MODE  7: CROSS RANGE  8: TRIGGER 9: PROTECTION 
10: MAX/MIN LIMIT 11: CAL PARAM.  12: OSCILLATE  13: BOOT INPUT
STEP PARAM.------- press ENTER key, use  to select number of Step COUNT then press ENTER. (0 ➔
1.
infinite)
MEASURE SENSE--press ENTER key, use  to select LOCAL / REMOTE sense then press ENTER.
2.
PORT0 ----------------press ENTER key, use  to enables or disables digit port the press ENTER.
3.
EXT. CONTROL-----press ENTER key, use  to select ON / OFF then press ENTER.
4.
SHORT CONTROL--press ENTER key, use  to select ON / OFF then press ENTER.
5.
CROSS MODE-------press ENTER key, use  to select INPUT OFF / INPUT REMAIN then press ENTER.
6.
CROSS RANGE----- press ENTER key, use  to select INPUT OFF / INPUT REMAIN then press ENTER.
7.
TRIGGER-------------press ENTER key, use  to select Source (Held, BUS, EXTERNAL, ETHERNET) /
8.
DELAY (in milli-second), then press ENTER.
9.
PROTECTION--------press ENTER key,
1: OV PROTECTION 2: UV PROTECTION  3: OC PROTECTION  4: UC PROTECTION
 5: OP PROTECTION 6: UP PROTECTION  7: V-ON CONTROL
1. OV PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
2. UV PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
3. OC PROTECTION--------------p ress ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
4. UC PROTECTION--------------p ress ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
5. OP PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
6. UP PROTECTION--------------press ENTER key, input the STATE/LIMIT/DELAY then press ENTER.
7. V-ON CONTROL--------------press ENTER key, input the STATE/V-ON THRESHOLD then press ENTER.
10. MAX/MIN LIMIT---press ENTER key,
1: MAX VOLTAGE 2: MIN VOLTAGE  3: MAX CURRENT  4: MIN CURRENT  5:
MAX RESISTOR 6: MIN RESISTOR  7: MAX POWER  8: MIN POWER