Safety Switch - Location Only; Replacing The Control Board Assembly And Power Supply Assembly - Extron electronics HSA 822M User Manual

Motorized hideaway surface access enclosure
Hide thumbs Also See for HSA 822M:
Table of Contents

Advertisement

im Vertrieb von
Maintenance and Modifications, cont'd
Safety Switch — Location only
The safety switch (figure 3-10) stops the downward motion of
platform when it encounters an obstruction to its smooth
operation. If an obstruction is present that blocks the platform's
travel, the stepper motor's carriage lifts and activates the safety
switch. The HSA's motor logic automatically reverses the
platform's motion and raises the platform to the upper position.
The carriage typically reverses with less than twelve pounds of
pressure applied to the obstruction.
Stepper
Motor and
Carriage
Assembly
Safety
Switch
Figure 3-10 — Location of the safety switch
(seen from the side)
The safety switch cannot be adjusted.
www.camboard.de
3-16
HSA 822M • Maintenance and Modifications
CAMBOARD Electronics
Replacing the Control Board Assembly and
Power Supply Assembly
Tel. 07131 911201
Fax 07131 911203
If they fail, the control board assembly (figure 3-1 on page 3-2,
) and the power supply assembly (
1
follows:
1.
Remove the surface mount enclosure from the table. See
Removing and Replacing the Enclosure, steps 1 through 12.
Place the enclosure on a horizontal surface. To protect the
finish, place the enclosure on a soft cloth.
2.
From the underside of the enclosure, reach into the cable
access holes (figure 3-1 on page 3-2, item
tie wraps
that route the AAP cables and network
5
(CAT 6) cables inside the enclosure.
3.
Remove the three screws (figure 3-1 on page 3-2, item
that secure the assembly to be replaced to the underside of
the enclosure.
For the control board assembly, screws indicated by an
asterisk (*) on figure 3-1 are accessible from the top
(inside the enclosure).
Do not remove screw
(figure 3-1 on page 3-2).
X
This screw does not secure the power supply assembly in
any way; rather, it provides structural support to the
enclosure.
4.
Remove all connectors from the assembly to be replaced.
5.
Remove the assembly from the enclosure.
6.
Secure the replacement assembly in the enclosure with the
screws removed in step 3.
7.
Reconnect all connectors removed in step 4.
8.
Retie all of the network (CAT 6) and AAP cables removed
in step 2 to the tie-downs (figure 3-1 on page 3-2, item
on the assembly that was replaced.
Reinstall the surface mount enclosure. See Removing and
9.
Replacing the Enclosure, steps 14 through 20.
ce-info@camboard.de
HSA 822M • Maintenance and Modifications
) can be replaced as
2
), and cut the
3
)
4
)
5
3-17

Advertisement

Table of Contents
loading

Table of Contents