Installation, cont'd

Cabling the RJ-45 connectors

Plug one end of a terminated CAT 5 or CAT 6 twisted pair (TP)
cable into each of these RJ-45 female connectors. Connect the
other end to an appropriate telecommunications or data
network device or to an Extron TP product.
An RJ-11 (telephone) plug can be connected to the RJ-45
jack.
The bottom RJ-45 connectors match up with the AAP/RJ-45
panel RJ-45 connectors as shown in figure 2-9. For example,
match the AAP/RJ-45 panel RJ-45 connector A1 with the
underside RJ-45 connector A1, match A2 with A2, and so forth.
A1
A2
A1
Figure 2-9 — HSA 822M RJ-45 connectors
If necessary, have a qualified service person replace the
connector icon on the AAP/RJ-45 panel by prying the old icon
off of the connector plug-in with a Tweeker or small screwdriver
(see figure 2-10) and snapping a new icon in place.
Icon Labels
Figure 2-10 — Changing the connector icon
www.camboard.de
2-12
HSA 822M • Installation
B1
B2
B1
B2
A2
CAMBOARD Electronics
Cabling the control and status captive screw
connector
Pin Definition
10
Tel. 07131 911201
Fax 07131 911203
Cut the tie wraps and remove the yellow shipping
CAUTION
restraint before testing the motorized mechanism.
Plug one end of the control cable(s) into this 10-pole captive
screw connector. Connect the other end of the cable(s) to a
control and/or monitoring system. The following table
identifies the signals on each pin of the connector.
Control and status connector pinout
1
2
3
4
5
6
Definition
1
Up (control)
Momentary
contact closure
2
Down (control)
Momentary
contact closure
3
Stop (control)
Momentary
contact closure
4
Gnd
Gnd
5
Enable
Contact closure
6
Up (status)
Grounded/
open
7
Down (status)
Grounded/
open
8
Gnd
Gnd
9
Power (status)
Grounded/
open
Gnd
Gnd
ce-info@camboard.de
HSA 822M • Installation
7
8
9
10
Explanation
Short to ground to raise
(open) the top panel.
Short to ground to lower
(shut) the top panel.
Short to ground to stop
the top panel's motion.
Ground
Short to ground to enable
activating the motor by
pressing on the top panel.
Grounded = up
Open = down or in motion
Grounded = down
Open = up or in motion
Ground
Grounded = AC power is
applied.
Open = No power is
applied.
Ground
2-13