2.
Shut off power to the drive, wait the appropriate amount of time for voltage to dissipate, then remove the
front cover (D).
Refer to the manual packaged with the drive for instructions on how to remove the cover.
NOTICE
can cause ESD damage to the option circuitry.
Note:
Remove the keypad, then move the keypad connector to the holder on the drive, then remove the front cover.
A - Holder
B - Keypad connector tab
C - Keypad connector
3.
Carefully remove the LED Status Ring board (A) and put it in the temporary placement holes (B) on the
right side of the drive.
Refer to the manual packaged with the drive for information about how to remove the LED Status Ring
board.
NOTICE
board, it can cause incorrect operation and damage to the drive.
A - LED Status Ring board
4.
Insert the option card (A) into the CN5-A connector (C) on the drive and use the included screws (B) to put
it in place.
• Tighten the screws to 0.5 to 0.6 N•m (4.4 to 5.3 in•lb).
Note:
1. A ground wire is not necessary. The option package ships with three screws and a ground wire for installation on other
product series. Do not use the ground wire or the extra screw.
2. Only two screws are necessary to install the option on GA700, GA800, CR700, and CH700 drives.
YASKAWA SIEP C730600 86F MECHATROLINK-II Technical Manual
Observe correct electrostatic discharge (ESD) procedures when touching the option. Failure to obey
Figure 5.11 Remove the Front Cover and Keypad
Do not remove the LED Status Ring board cable connector. If you disconnect the LED Status Ring
Figure 5.12 Remove the LED Status Ring Board
D - Drive front cover