Mechanical Assembly; Control Terminal; Disassembly Of Control Terminal; Opening Of The Control Terminal - GE eBike II Series Service Manual

Table of Contents

Advertisement

M
eCHanICal asseMBly
C
ontrol terMInal
d
IsasseMBly of Control terMInal
Loose both Phillips-head screws at the side of the control
terminal.
Remove the control terminal from the support.
Disconnect the patch cable from the ZME board.
Ergometer with option bloodpressure:
Disconnect the microfon cable by pulling out the 3
pole jack.(see picture)
Disconnect the blue hose at the hose connector
(see picture).
Caution
Do not twist the microphone cable connector -
the cable will be damaged!
o
penIng of tHe Control terMInal
Loose the 4 Phillips head screws at the bottom of the
housing.
Lift carefully the upper part of the housing (with the foil
keyboard) and disconnect the cable from the ZME board.
The front panel is plugged into the enclosure and can be
easily removed.
- 40 -
eBike II, eBike II L, eBike II EL
2018112-069 Rev. F