Error Code Bits Com - GE eBike II Series Service Manual

Table of Contents

Advertisement

e
CoM
rror Code BIts
Bit
Error
0
not used
1
not used
2
not used
3
not used
4
+24V out of range
5
not used
6
not used
7
Safety state mode
8
Setup not ready
9
CAN zykl. Timeout
- 138 -
Reaction
Display / Info
Warning
Module is switched off
Internal error
Module is switched off
Internal error
Module is switched off
Internal error
eBike II, eBike II L, eBike II EL
Troubleshooting
- check mounting of COM
(DSUB connector)
- check jumper on BKE
- check power supply
- check connections:
power supply to LRE
cable LRE <-> BKE
- replace COM
- restart eBike (OFF / ON)
- check mounting of COM
(DSUB connector)
- check jumper on BKE
- if error persists: replace COM
- check mounting of COM
(DSUB connector)
- check jumper on BKE
- restart eBike (OFF / ON)
- if error persists: replace COM
- check mounting of COM
(DSUB connector)
- check jumper on BKE
- restart eBike (OFF / ON)
- if error persists: replace COM