Festo CPX-FB14 Electronic Manual page 109

Terminal fieldbus node
Hide thumbs Also See for CPX-FB14:
Table of Contents

Advertisement

2. Commissioning
Index
Sub
Designa
(hex)
index
tion
4000
Function
assignment
mask
enable
enable
4001
0
Function
assignment
assignment
1
mask inputs
10
h
4200
0
Function
assignment
assignment
1
mask
10
outputs
h
4800
0
Set module
config
function
function
1
assignment
48
Festo P.BE−CPX−FB14−E N en 0810b
Type Attr. Map. Values
Bool
rw
U8
rw
U8
rw
U8
rw
U32
Explanation
(hex)
0
Function assignment and
virtual modules
deactivated
1
Function assignment and
virtual modules activated
0
10
Number of entries
xx
0 = enter virtual bits in
object 6000 (input
array)
1 = enter physically
present bits in object
6000 (input array)
(default setting)
0
10
Number of entries
xx
0 = enter virtual bits in
object 6200 (output
array)
1 = enter physically
present bits in object
6200 (output array)
(default setting)
0
30h
Number of the
configuration entries used
With these entries, a possible system
structure including virtual modules is
defined.
Byte 0: number of output bits (digital
modules) or number of output bytes
(analogue modules)
Byte 1: as with byte 0 but for the inputs
Byte 2: CPX module code specification
(with 0 = no module code specification)
Byte 3:
Bit 7: 0 = physically present module,
1 = virtual module
Bit 6 ... 2: reserved
Bit 1 ... 0: modul type: 00 = digital,
01 = analogue, 10 = technology module