2. Commissioning
2.5
Parameterizing
2.5.1 Parameterizing when switching on
1
Parameterization
is loaded into the
node by the
master
2
Parameterization
is distributed to
the modules by
the node
Fig. 2/8: Sequence of start parameterization
2−68
You can set the reaction of the CPX terminal in the operating
mode Remote I/O by individual parameterizing. A distinction
is made between the following parametrizations:
System parameterization, e.g.: switching off fault mess
ages, etc.
Parameterization of the diagnostic memory.
Module parameterization (module and channel−specific),
e.g.: monitoring, settings in the event of errors, settings
for the debounce times of the inputs.
Recommendation:
Parameterize the CPX terminal via the SDO in pre−operational
mode.
A detailed description of the individual parameters as well as
basic information on application can be found in the CPX
system manual (P.BE−CPX−SYS−...).
Parameter lists for CPX I/O modules and CPX pneumatic
interfaces can be found in the description of CPX I/O modules
(P.BE−CPX−EA−...).