Annex: Control Motors - Hanskamp SpiderServer Installation And Operating Instructions Manual

Feeding computer
Table of Contents

Advertisement

EN
Voercomputer—Feeding computer—Fütterungscomputer—ordinateur d'alimentation
13.5 Annex control motors
Engine
Possible
Solidstate 5
Yes – Standard
Solidstate+
Rather not
Intelligent
Yes
motor
RIM puls
Yes
RIM time
Yes
Grey motor
Yes
Black Nedap
Yes
motor
AC motoren
No
DC time-
Yes
controlled
motors
Index
Hanskamp AgroTech B.V. (the Netherlands)
Feedback
Notes
Yes
No
Old motor - Preferably replace with a Solidstate 5. Solidstate +
can be used. Connect brown, white and green, and add a 2k2
resistor to green and grey.
No
More expensive motor and no feedback, do not recommend.
No
More expensive motor. Do not connect feedback.
No
More expensive motor. Do not connect feedback.
Yes
Downside to sliders and less stronger because it is 40 RPM. Pref-
erably replace with a Solidstate 5.
Yes
Huge disadvantages are the sliders and the fact that this motor
draws much more current. Preferably replace it with a Solidstate
5. When connecting a Nedap motor, connect red to the green
connection.
No
Using a relay it would be possible but without feedback. Not test-
ed, so no. Not anti-spill.
No
Not what we would advise, but it is possible. Not anti-spill.
66 - 68
www.hanskamp.nl/en
Spider

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spider seriesSpiderclient

Table of Contents