4.3.6 Updating firmware

This menu contains a number of settings that are normally set correctly with tag tuning but that can be changed manually
here.
Id
Description
30011
Enable Tagtypes
30001
RFID:Frequency
30002
RFID: Multiplextime, the time an antenne is active (not
HDX/Delaval)
30003
FRID: Holdtime, the maximum time between 2 reads
30007
RFID: Syncmode (0=off/1=on)
30011 Enable Tagtypes: Specify the tagtype used. By adding up the values, multiple types of transponders can be
read. Contact Hanskamp for more information about the possibilities.
30001 RFIDFrequency: Enter the best frequency for this tag in combination with the antenna. To fine-tune, increase
and decrease this value in steps of 500 to find the best setting for your situation.
30002 RFID Multiplextime: Now, the antenna is on to read a tag. There is never more than one antenna active at a
time. For slower transponders with a longer loading time, this value can be set higher (e.g. for tagtype 16, this
setting should be at 2000). This setting is not used for HDX or Delaval. In that situation, the Burst and Listentime
must be set correctly.
30003 RFID Holdtime: Now, the tag must be read again to confirm that the same cow is still present. If the cow is
not recognised every 3000 msec, this time can be increased. This allows the feeding process to continue during the
Holdtime; if no cow is identified during the Holdtime, the feeding process will stop.
30007 RFID LEDS: set this to 1, to activate an extra "service" function in the LED indicator. On the front of the Spider
unit, the LED corresponding to the active antenna turns red. When a transponder is detected, the LED will light up/
flash green. This is handy for testing and fine-tuning the antennas. This setting is set to 0 by default to keep the LED
indicator clear.
Check "Advanced settings" to view and change more settings.
Index
Hanskamp AgroTech B.V. (the Netherlands)
Value
2
Tagtypes:
HDX=1
FDX_B=2
DELAVAL=4
EM410x=8
NEDAP 1e gen=16
NEDAP 2e gen=32
VCODE=64
ID2000=128
FULLWOOD=256
ALL=4294967295
Combi: HDX(1)+DELAVAL(4)=5
134200
Freq: 110000...145000 Hz
300
3000
0
25 - 68
www.hanskamp.nl/en
Spider
Save
Save
Save
Save
Save