Installation In The Milking-Parlour; Connecting The Limit Switch - Hanskamp SpiderServer Installation And Operating Instructions Manual

Feeding computer
Table of Contents

Advertisement

EN
Voercomputer—Feeding computer—Fütterungscomputer—ordinateur d'alimentation
3.3 Installation in the milking parlour
Because the Spider has 16 antenna inputs and 16 feed outputs, it can also be used for individual feeding in the milking parlour.
Every position can be seen as a feeding station. Please refer to chapter 3.2.1 to connect it.

3.3.1 Connecting the limit switch

A limit switch can be installed to prevent animals from being recognised and stopping before the last stall. The limit switch de-
activates the antennas during the switch. This prevents feeding until all the cows are in the correct position.
This example shows the correct set up for a 2x8 milking parlour.
The antennas are inoperative when the
switch is operated. Connect the brown and
green wires. (NO)
The antennas are inoperative when the
switch is not operated. Connect the brown
and Yellow wires. (NC)
Read yellow as green direction the Spider PCB
Detection port
1
2
3
4
This can be forwarded as in the example. In this instance, one switch is used for feeders 1-8 and one for feeders 9-16.
Index
Hanskamp AgroTech B.V. (the Netherlands)
Detection 1 and 2 are connected in this example
Milking parlor 2x8
Side A
works for feeder
1-4
works for feeder
5-8
works for feeder
9-12
works for feeder
13-16
www.hanskamp.nl/en
Side B
18 - 68