If you are mounting a PTX10003 in a rack with other equipment, ensure that the exhaust from other
equipment does not blow into the intake vents of the chassis.
You must leave at least 24 in. (61 cm) both in front of and behind the PTX10003 for service personnel
to remove and install hardware components.
PTX10003 Chassis Physical Specifications
Table 23 on page 76
lists the physical specifications for the PTX10003 chassis.
Table 23: Physical Specifications for the PTX10003
Hardware
Weight
Dimension (WxHxD)
Rack Units
PTX10003 Rack Requirements
The PTX10003 chassis is designed to be installed in a four-post 19-in rack.
Rack requirements consist of:
Rack type
Mounting bracket hole spacing
Rack size and strength
Rack connection to the building structure
Table 24 on page 77
provides the rack requirements and specifications for the PTX10003.
PTX10003-160C
110 lb (50 kg)
17.4 x 5.25 x 31 in (44.2 x 13.3 x 78.7 cm)
3 U, fits in a 19" rack
PTX10003-80C
88 lb (40 kg)
17.4 x 5.25 x 31 in (44.2 x 13.3 x 78.7 cm)
3 U, fits in a 19" rack