Configuring Common Settings For Console Login (Optional) - HP A-F1000-E Getting Started Manual

High-end firewalls
Table of Contents

Advertisement

Figure 16 Configuration page

Configuring common settings for console login (optional)

Follow these steps to configure common settings for console port login
To do...
Enter system view
Enable display of copyright
information
Enter console user interface view
Configure
console port
properties
Use the
command...
system-view
copyright-info
enable
user-interface
console
first-number
[ last-number ]
Configure the
speed speed-value
baud rate
parity { even |
Configure the
mark | none | odd
parity check mode
| space }
Configure the stop
stopbits { 1 | 1.5 |
bits
2 }
Remarks
Optional
Enabled by default.
Optional
By default, the transmission rate is 9600 bps.
Transmission rate is the number of bits that the
device transmits to the terminal per second.
Optional
none by default.
Optional
By default, the stop bits of the console port is 1.
Stop bits are the last bits transmitted in data
transmission to unequivocally indicate the end of a
character. The more the bits are, the slower the
transmission is.