______________________________________________________ MODEL
______________________________________________________
_________________________________________________________
NOTE!
_________________________________________________________
PORTUSE1
PORTUSE2
PORTUSE3
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
54
When changing serial port assignments using
PORTUSE1, PORTUSE2, and PORTUSE3, selecting
remote front panel (REMOTEFP) for a serial port,
which is not actually connected to a remote front panel,
results in loss of control of the unit. Control is regained
by simultaneously pressing the zero, decimal, and
minus keys on the unit's front panel keypad.
Downloading the Model 2500 can only be done through the
SLAVE port, not SLAVE #2. If 2 SLAVE ports are required
with one SLAVE port assigned to each board, a two-board unit
is required.
PORTUSE1 lower level sub-menu provides for displaying
or changing the way serial port number 1 is being used
(NONE, REPORTS, SLAVE, MASTER, REMOTEFP,
USERCOMM), with the default being REPORTS.
PORTUSE2 lower level sub-menu provides for displaying
or changing the way serial port number 2 is being used
(NONE, REPORTS, SLAVE, MASTER, REMOTEFP,
USERCOMM), with the default being SLAVE.
PORTUSE3 lower level sub-menu provides for displaying
or changing the way serial port number 3 is being used
on a two-board unit (NONE, REPORTS, SLAVE,
MASTER, REMOTEFP, USERCOMM), with the default
being NONE.
MODEL 2500
2500
SECTION 4 4
SECTION