DANIEL 2500 User's Reference Manual page 52

Table of Contents

Advertisement

______________________________________________________
______________________________________________________ MODEL
6.
Press the number 1 key 8 times, which will cause the default password,
"11111111" to appear on the LCD screen,
7.
Press the ENTER key. This will cause the green LED on the front panel to
glow.
_________________________________________________________
NOTE!
_________________________________________________________
8.
Scroll to the desired sub-menu and lower sub-menu by pressing the arrow
keys.
9.
Key in new or revised data, and enter the data by pressing the ENTER key.
_________________________________________________________
CAUTION!
_________________________________________________________
10.
Press the arrow keys when data entry is complete to find the lower sub-menu
UNIT LOCK located in the sub-menu SYSTEM COMMANDS.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
38
The password may be changed at this time by keying in
eight numbers on the front panel keypad. (The MODEL
2500 accepts prefixed zeros as discrete, which means the
instrument requires all eight digits of a number such as
00000004 in order to interpret the number 4 as the
password.) When the new password has been keyed in,
press the ENTER key. The keyboard now can be
unlocked for data entry only with the new password.
The password cannot be retrieved once entered, and
should be recorded in a secure location.
Changing values in the Model 2500 system may
activate alarms, which must be cleared before
placing the unit in service.