Examples For Locating And Entering Data Tables - DANIEL 2500 User's Reference Manual

Table of Contents

Advertisement

______________________________________________________ MODEL
______________________________________________________

EXAMPLES FOR LOCATING AND ENTERING DATA TABLES

This section presents examples involved in locating, displaying and entering data
on data tables. In addressing the steps or procedures involved in accomplishing this,
the specific application example chosen to demonstrate this will be "Application
Number 51119110".
In this application example, a typical table, TABLE 18, is used. TABLE 18
contains values of K, which are used in determining a Reynolds number factor by
means of a calculation. K values depend on the orifice meter tap type and the value
of BETA, which is the ratio between the orifice diameter and the pipe diameter.
TABLE 18, as it would typically appear in printed form, is illustrated below.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
104
TABLE 18
BETA 0.100
BETA 0.125
BETA 0.150
BETA 0.175
BETA 0.200
BETA 0.225
BETA 0.250
BETA 0.275
BETA 0.300
BETA 0.325
TAPTYPE
1
2
0.607
0.604
0.608
0.604
0.611
0.604
0.614
0.604
0.618
0.604
0.623
0.605
0.628
0.605
0.634
0.606
0.641
0.606
0.650
0.607
MODEL 2500
2500
SECTION 6 6
SECTION

Hide quick links:

Advertisement

Table of Contents