Number
Severity
Description/Recommended actions
Recommended actions:
313
Error
The indicated controller module has failed. This event can be ignored for a single-controller configuration.
Recommended actions:
314
Error
The indicated FRU has failed or is not operating correctly. This event follows some other FRU-specific event
indicating a problem.
Recommended actions:
315
Critical
This IOM is incompatible with the enclosure in which it is inserted.
Recommended actions:
316
Warning
The temporary license for a feature has expired.
Any components created with the feature remain accessible but new components cannot be created.
Recommended actions:
Info.
The temporary license for a feature will expire in 10 days. Any components created with the feature will
remain accessible but new components cannot be created.
Recommended actions:
317
Error
A serious error has been detected on the Storage Controller's disk interface. The controller will be killed by its
partner.
Recommended actions:
319
Warning
The indicated available disk has failed.
Recommended actions:
322
Warning
The controller has an older Storage Controller (SC) version than the version used to create the CHAP
authentication database in the controller's flash memory.
The CHAP database cannot be read or updated. However, new records can be added, which will replace the
existing database with a new database using the latest known version number.
Recommended actions:
352
Info.
Expander Controller (EC) assert data or stack-dump data are available.
Recommended actions:
No action is required.
If this is a dual-controller system, replace the failed controller module. The module's Fault/Service
Required LED will be illuminated (not blinking).
To determine whether the FRU needs to be replaced, see the topic about verifying component failure in
your product's Hardware Installation and Maintenance Guide.
Replace this IOM with an IOM that is compatible with this enclosure.
To continue using the feature, purchase a permanent license.
To continue using the feature after the trial period, purchase a permanent license.
Visually trace the cabling between the controller modules and expansion modules.
If the cabling is OK, replace the controller module that logged this event.
If the problem recurs, replace the expansion module that is connected to the controller module.
Replace the disk with one of the same type (SSD, enterprise SAS, or midline SAS) and the same or
greater capacity. For continued optimum I/O performance, the replacement disk should have
performance that is the same as or better than the one it is replacing.
Upgrade the controller firmware to a version whose SC is compatible with the indicated database version.
If no records were added, the database becomes accessible and remains intact.
If records were added, the database becomes accessible but contains only the new records.