Dell EMC ME4084 Owner's Manual page 66

Hide thumbs Also See for ME4084:
Table of Contents

Advertisement

Number
Severity
Info.
7
Error
8
Warning
66
Events and event messages
Description/Recommended actions
Either:
Disk group creation completed successfully.
Disk group creation failed immediately. The user was given immediate feedback that it failed at the time
they attempted to add the disk group.
Recommended actions:
No action is required.
In a testing environment, a controller diagnostic failed and reports a product-specific diagnostic code.
Recommended actions:
Perform failure analysis.
One of the following conditions has occurred:
A disk that was part of a disk group is down. The indicated disk in the indicated disk group failed and the
disk group probably has a status of FTDN (fault tolerant with a down disk), CRIT (critical), or OFFL
(offline), depending on the RAID level and the number of disks that failed. If a spare is present and the
disk group is not offline, the controller automatically uses the spare to reconstruct the disk group.
Subsequent events indicate the changes that happen to the disk group. When the problem is resolved,
event 9 is logged.
Reconstruction of a disk group failed. The indicated disk was being used as the target disk for
reconstructing the indicated disk group. While the disk group was reconstructing, another disk in the disk
group failed and the status of the disk group went to OFFL (offline). The indicated disk has a status of
LEFTOVR (leftover).
An SSD that was part of a disk group has reported that it has no life remaining. The indicated disk in the
indicated disk group failed and the disk group probably has a status of FTDN (fault tolerant with a down
disk), CRIT (critical), or OFFL (offline), depending on the RAID level and the number of disks that failed. If
a spare is present and the disk group is not offline, the controller automatically uses the spare to
reconstruct the disk group. Subsequent events indicate the changes that happen to the disk group. When
the problem is resolved, event 9 is logged.
Recommended actions:
If a disk that was part of a disk group is down:
If the indicated disk failed for one of these reasons—excessive media errors, imminent disk failure,
possible hardware failure, disk is not supported, too many controller-recoverable errors, illegal request,
due to being degraded, or due to being too slow—replace the disk with one of the same type (SSD,
enterprise SAS, or midline SAS) and the same or greater capacity. For continued optimum I/O
performance, the replacement disk should have performance that is the same as or better than the
one it is replacing.
If the indicated disk failed because a user forced the disk out of the disk group, RAID-6 initialization
failed, or for an unknown reason:
If the associated disk group is offline or quarantined, contact technical support.
Otherwise, clear the disk's metadata to reuse the disk.
If the indicated disk failed because a previously detected disk is no longer present:
Reinsert the disk or insert a replacement disk of the same type (SSD, enterprise SAS, or midline
SAS) and the same or greater capacity as the one that was in the slot. For continued optimum I/O
performance, the replacement disk should have performance that is the same as or better than
the one it is replacing.
If the disk then has a status of leftover (LEFTOVR), clear the metadata to reuse the disk.
If the associated disk group is offline or quarantined, contact technical support.
If reconstruction of a disk group failed:
If the associated disk group is online, clear the indicated disk's metadata so that the disk can be re-
used.
If the associated disk group is offline, the CLI trust command may be able to recover some or all of
the data in the disk group. However, trusting a partially reconstructed disk may lead to data
corruption. See the CLI help for the trust command. Contact technical support for help to
determine if the trust operation applies to your situation and for help to perform it.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me4024Powervault me4 series

Table of Contents