Events (Continued) - Dell EMC ME4084 Owner's Manual

Hide thumbs Also See for ME4084:
Table of Contents

Advertisement

Number
Severity
Info.
362
Critical, Error,
or Warning
Info.
363
Error
Info.
364
Info.
365
Error
Warning

Events (continued)

Number
Severity
400
Info.
Description/Recommended actions
Recommended actions:
Take appropriate action based on the indicated problem.
A scheduled task was initiated.
Recommended actions:
No action is required.
The scheduler experienced a problem with the indicated task.
Recommended actions:
Take appropriate action based on the indicated problem.
The scheduler experienced a problem with the indicated task.
Recommended actions:
No action is required.
When the Management Controller (MC) is restarted, firmware versions that are currently installed are
compared against those in the bundle that was most recently installed. When firmware is updated, it is
important that all components are successfully updated or the system may not work correctly. Components
checked include the CPLD, Expander Controller (EC), Storage Controller (SC), and MC.
Recommended actions:
Reinstall the firmware bundle.
When the Management Controller (MC) is restarted, firmware versions that are currently installed are
compared against those in the bundle that was most recently installed. If the versions match, this event is
logged as Informational severity. Components checked include the CPLD, Expander Controller (EC), Storage
Controller (SC), and MC.
Recommended actions:
No action is required.
The broadcast bus is running as generation 1.
Recommended actions:
No action is required.
An uncorrectable ECC error occurred in Storage Controller CPU memory more than once, indicating a
probable hardware fault.
Recommended actions:
Replace the controller module that logged this event.
An uncorrectable ECC error occurred in Storage Controller CPU memory.
This event is logged with Warning severity to provide information that may be useful to technical support, but
no action is required now. It will be logged with Error severity if it is necessary to replace the controller
module.
Recommended actions:
No action is required.
Description/Recommended actions
The indicated log has filled to a level at which it needs to be transferred to a log-collection system.
Recommended actions:
Events and event messages
97