Dell EMC ME4084 Owner's Manual page 132

Hide thumbs Also See for ME4084:
Table of Contents

Advertisement

Number
Severity
612
Info.
613
Error
Warning
Info.
Resolved
615
Info.
616
Warning
Info.
617
Warning
618
Resolved
619
Error
132
Events and event messages
Description/Recommended actions
Verify the configured parameters and ask the recipients to confirm that they received the message.
An alert condition was detected on an internal chassis SAS connector.
The event message specifies the location of the internal SAS connector in the chassis.
Recommended actions:
No action is required.
An alert condition was detected on an IOM.
Recommended actions:
Either install the indicated IOM or attempt to reseat it.
If the problem persists, replace the IOM.
An alert condition was detected on an IOM.
Recommended actions:
If uninstalled, install the indicated IOM otherwise attempt to reseat it.
If the problem persists, replace the IOM.
An IOM was uninstalled.
Recommended actions:
No action is required.
A previous Warning or Error condition for the IOM has been resolved.
Recommended actions:
No action is required.
A rebalance operation for an ADAPT disk group has started.
Recommended actions:
No action is required.
A rebalance operation for an ADAPT disk group has completed partially (because of drive failure).
Recommended actions:
No action is required.
A rebalance operation for an ADAPT disk group has completed.
Recommended actions:
No action is required.
The spare capacity goal is not met.
This event indicates that the available space in the system is insufficient to provide the level of full fault
tolerance that is specified by the target spare capacity. Spare capacity availability can be influenced by
operations that require available space in the system, such as reconstructing data from a failed disk.
Recommended actions:
Add disks to the disk group, or replace any disks that may have failed. The system will automatically
increase the spare capacity to meet the requirements placed on the system by the target spare capacity.
The spare capacity goal is met.
Recommended actions:
No action is required.
Disk access will change depending on the port used to connect to the expander.
Recommended actions: