Number
Severity
Description/Recommended actions
Warning
An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
The fan management device in the enclosure reports bad voltage on one or both fan control modules.
Recommended actions:
Resolved
An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
A SES alert for a fan management device in the indicated enclosure has been resolved.
Recommended actions:
561
Error
An Enclosure Management Processor (EMP) reported an alert condition on the front panel ear LED.
The EMP is unable to communicate with the front panel ear LED.
Recommended actions:
Info.
An Enclosure Management Processor (EMP) reported an alert condition on the front panel ear LED.
Recommended actions:
Resolved
An Enclosure Management Processor (EMP) reported an alert condition on the front panel ear LED.
A SES alert for a front panel ear LED in the indicated enclosure has been resolved.
Recommended actions:
562
Info.
Virtual pool statistics have been reset.
Recommended actions:
563
Info.
A disk has been restarted.
Recommended actions:
564
Error
An Enclosure Management Processor (EMP) reported an alert condition in a drawer of the enclosure.
system to avoid risk of damage. Replace the chassis FRU immediately. If a temperature sensor reaches a
shutdown value, the controller module will automatically shut down. For shutdown values, see information
about temperature sensors in your product's installation guide.
If you can get to the physical location of the enclosure within 10 minutes of this event being logged, check
whether the fans are operating in the enclosure.
If the fans are operating then an over-temperature condition should not occur. The fans should be
operating at their highest RPM rate. Replace the chassis FRU at a specified service interval.
If the fans are not operating then an over-temperature condition will likely occur. If possible, shut down
the system now to avoid risk of damage. Replace the chassis FRU immediately.
If you cannot get to the physical enclosure location within 10 minutes of this event being logged:
Monitor system temperatures (temperature sensors and disks) closely to ensure that an over-
temperature condition is not occurring.
If system temperatures steadily climb, if possible shut down the system to avoid risk of damage. Replace
the chassis FRU immediately. If a temperature sensor reaches a shutdown value, the controller module
will automatically shut down. For shutdown values, see information about temperature sensors in your
product's installation guide.
Inspect the status of the fan management device in system health. If either of the fan modules also
reports failure, replace them.
No action is required.
Replace the chassis-and-midplane FRU for the indicated enclosure.
When the problem is resolved, an event with the same code will be logged with Resolved severity.
No action is required.
No action is required.
No action is required.
No action is required.