Events and event messages
Description/Recommended actions
The mirrored configuration retrieved by this controller from the partner controller has a configuration level
that is too high for the firmware in this controller to process. The local flash configuration will be used instead.
Recommended actions:
The current controller that logged this event probably has down-level firmware. Update the firmware in
the down-level controller. Both controllers should have the same firmware versions.
When the problem is resolved, event 20 is logged.
The partner controller does not have a mirrored configuration image for the current controller, so the current
controller's local flash configuration is being used.
This event is expected if the other controller is new or its configuration has been changed.
Recommended actions:
No action is required.
In a testing environment, the diagnostic that checks hardware reset signals between controllers in Active-
Active mode failed.
Recommended actions:
Perform failure analysis.
Both controllers in an Active-Active configuration have the same serial number. Non-unique serial numbers
can cause system problems. For example, WWNs are determined by serial number.
Recommended actions:
Remove one of the controller modules and insert a replacement, then return the removed module to be
reprogrammed.
Pending configuration changes that take effect at startup were ignored because customer data might be
present in cache.
Recommended actions:
If the requested configuration changes did not occur, make the changes again and then use a user-
interface command to shut down the Storage Controller and then restart it.
The name has been changed for the indicated volume.
Recommended actions:
No action is required.
The size has been changed for the indicated volume.
Recommended actions:
No action is required.
The default LUN (logical unit number) has been changed for the indicated volume.
Recommended actions:
No action is required.
The indicated volume has been added to the indicated pool.
Recommended actions:
No action is required.
A serious error has been detected by the controller. In a single-controller configuration, the controller will
restart automatically. In an Active-Active configuration, the partner controller will kill the controller that
experienced the error.
Recommended actions:
Download the debug logs from your storage system and contact technical support. A service technician
can use the debug logs to determine the problem.