Number
Severity
591
Error
Resolved
593
Info.
594
Info.
128
Events and event messages
Description/Recommended actions
being quarantined. For example, if the disk group was reconstructing before being quarantined, the disk
group will resume reconstructing where it stopped
For a linear disk group, if you want to find where parity is incorrect, use the CLI scrub vdisk command
with the fix parameter disabled. This step is optional and not required to fix data integrity issues
For a fault tolerant disk group, run either scrub disk-groups for a virtual disk group or scrub
vdisk with the fix parameter enabled for a linear disk group. This step will make the parity consistent
with the existing user data, and is required to fix data integrity issues.
For a reconstructing disk group, let reconstruction finish, then run either scrub disk-groups for a
virtual disk group or scrub vdisk with the fix parameter enabled for a linear disk group. This step will
make the parity consistent with the existing user data, and is required to fix data integrity issues.
Restore the data to the disk group from a backup copy.
A controller module has been fenced because of a failure or a controller module has been unfenced.
The indicated controller module is malfunctioning and has been isolated from the system. When the problem
is resolved, an event with the same code will be logged with Informational severity.
Recommended actions:
Replace the controller module that logged this event.
A controller module has been fenced because of a failure or a controller module has been unfenced.
A malfunction that caused the indicated controller module to be fenced has been resolved, and the controller
module has been returned to service.
Recommended actions:
No action is required.
A PCIe bus has transitioned to a different speed.
Recommended actions:
No action is required.
The indicated disk in the indicated disk group is missing and the disk group is quarantined. While the disk
group is quarantined, in linear storage any attempt to access its volumes from a host will fail. In virtual
storage, all volumes in the pool will be forced read-only. If all of the disks become accessible, the disk group
will be dequarantined automatically with a resulting status of FTOL. If not all of the disks become accessible
but enough become accessible to allow reading from and writing to the disk group, it will be dequarantined
automatically with a resulting status of FTDN or CRIT. If a spare disk is available, reconstruction will begin
automatically. When the disk group has been removed from quarantine, event 173 is logged. For a more
detailed discussion of dequarantine, see the WBI or CLI documentation.
CAUTION:
Avoid using the manual dequarantine operation as a recovery method when event 172 is
logged because this causes data recovery to be more difficult or impossible.
If you clear unwritten cache data while a disk group is quarantined or offline, that data will
be permanently lost.
Recommended actions:
If event 173 has subsequently been logged for the indicated disk group, no action is required. The disk
group has already been removed from quarantine.
Otherwise, perform the following actions:
Check that all enclosures are powered on.
Check that all disks and I/O modules in every enclosure are fully seated in their slots and that their
latches are locked.
Reseat any disks in the quarantined disk group that are reported as missing or failed in the user
interface. (Do NOT remove and reinsert disks that are not members of the disk group that is
quarantined.)