Number
Severity
Description/Recommended actions
Recommended actions:
235
Error
An enclosure management processor (EMP) detected a serious error.
Recommended actions:
Info.
An enclosure management processor (EMP) reported an event.
Recommended actions:
236
Error
A special shutdown operation has started. These special shutdown types indicate an incompatible feature.
Recommended actions:
Info.
A special shutdown operation has started. These special shutdown types are used as part of the firmware-
update process.
Recommended actions:
237
Error
A firmware update attempt was aborted because of either general system health issue(s), or unwritable
cache data that would be lost during a firmware update.
Recommended actions:
Info.
A firmware update has started and is in progress. This event provides details of the steps in a firmware-
update operation that may be of interest if you have problems updating firmware.
Recommended actions:
238
Warning
An attempt to install a licensed feature failed due to an invalid license.
Recommended actions:
239
Warning
A timeout occurred while flushing the CompactFlash.
Recommended actions:
240
Warning
A failure occurred while flushing the CompactFlash.
Recommended actions:
241
Info.
The auto-write-through trigger event that caused event 242 to be logged has been resolved.
Recommended actions:
242
Error
The controller module's CompactFlash card has failed.
All the snapshots associated with this snap pool are invalid and you may want to delete them. However,
the data in the master volume can be recovered by converting it to a standard volume.
Replace the indicated controller module or expansion module.
No action is required.
Replace the indicated controller module with one that supports the indicated feature.
No action is required.
Resolve before retrying a firmware update. For health issues, issue the CLI show system command to
determine the specific health issue(s). For unwritten cache data, use the CLI show unwritable-
cache command
No action is required.
Check the license for what is allowed for the platform, make corrections as appropriate, and reinstall.
Restart the Storage Controller that logged this event.
If this event is logged again, shut down the Storage Controller and replace the CompactFlash.
Restart the Storage Controller that logged this event.
If this event is logged again, shut down the Storage Controller and replace the CompactFlash.
If this event is logged again, shut down the Storage Controller and replace the controller module.
No action is required.