Number
Severity
Description/Recommended actions
466
Info.
The indicated virtual pool was deleted.
Recommended actions:
467
Info.
Addition of the indicated disk group completed successfully.
Recommended actions:
468
Info.
FPGA temperature has returned to the normal operating range and the speed of buses connecting the FPGA
to downstream adapters has been restored. The speed was reduced to compensate for an FPGA over-
temperature condition.
This event indicates that a problem reported by event 469 is resolved.
Recommended actions:
469
Warning
The speed of buses connecting the FPGA to downstream adapters has been reduced to compensate for an
FPGA over-temperature condition.
The storage system is operational but I/O performance is reduced.
Recommended actions:
When the problem is resolved, event 468 is logged.
470
Warning
Removal of the indicated disk group(s) completed with failure.
Removal of disk groups can fail for several reasons, and the specific reason for this failure is included with the
event. Removal most often fails because there is no longer room in the remaining pool space to move data
pages off of the disks in the disk group.
Recommended actions:
Info.
Removal of the indicated disk group(s) completed successfully.
Recommended actions:
471
Error
A replication was queued because the secondary volume is detached.
Recommended actions:
473
Info.
The indicated volume is using more than its threshold percentage of its virtual pool.
This is an indication that the storage usage crossed the user-specified threshold for this volume. If the
storage usage drops below the threshold, event 474 is logged.
Recommended actions:
474
Info.
The indicated volume is no longer using more than its threshold percentage of its virtual pool.
This event indicates that the condition reported by event 473 is no longer applicable.
No action is required.
No action is required.
No action is required.
Check that the storage system's fans are running.
Check that the ambient temperature is not too warm. The controller enclosure operating range is 5°C to
35°C (41°F to 95°F). The expansion enclosure operating range is 5°C to 40°C (41°F to 104°F).
Check for any obstructions to the airflow.
Check that there is a module or blank plate in every module slot in the enclosure.
If none of these recommended actions resolve the issue, replace the controller module that logged the
error.
Resolve the issue specified by the error messaging included with this event and re-issue the request to
remove the disk group.
No action is required.
To allow the replication to proceed, reattach the secondary volume and then resume the replication.
No action is required. How this information is utilized is left to the discretion of the user.