ReMARKs on InstALLAtIon
Note that:
• installation must be carried out by authorised
technical personnel;
• The appliance must be installed and operated
in compliance with local and national law and
European regulations. The applicable Italian
standard is UNI 10683;
• If installed in a condominium, the appliance must
be approved by the administrator.
We give some general instructions below, however
these do not obviate the need to comply with local
regulations and do not imply any liability as regards
the installer's work.
Checking the suitability of the installation
space
• The room must have a volume of at least 15 m
• The floor must be able to bear the weight of the
product and its accessories.
• Level the product (the product is provided with
adjustable feet).
• The appliance may not be installed in a bedroom,
bathroom or in the same room as other equipment
which draws air for combustion from the room
itself, or in any area with an explosive atmosphere.
Any extraction fans operating in the same room or
area as the product, may affect its draw.
• In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas fired
products.
ADJUstAbLe feet
The boiler stoves (Kira H and Vyda H) are provided
with adjustable feet for better positioning on the floor.
The feet are adjustable in height using a screwdriver
at the top of the foot and can slightly raise the boiler
stove.
InstALLAtIon
protection from heat and safety clearances
The surfaces of the building that are adjacent to the
product must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
The appliance must be installed in accordance with
the following safety instructions:
- no flammable materials may be kept closer than 15
cm to the sides and back
- no flammable materials may be kept within 80 cm
from the front of the appliance.
If connected to a wooden or otherwise flammable wall,
the flue must be insulated appropriately.
If installed on a flammable or combustible floor, or
which is not capable of bearing its load, use steel or
glass plates under the stove to distribute the load.
Information on positioning the product
The product is designed to operate in all climatic
.
3
conditions. In special circumstances, such as strong
wind, its safety equipment may switch the appliance
off.
Contact the authorised Edilkamin Technical Assistance
Centre.