  • Page 1 MILLA H PELLET BOILER STOVE Installation, use and maintenance page...
  • Page 2: Table Of Contents

    SERIAL NO.: Rating plate reference MILLA H 12: Performance declaration (DoP - EK n° 174a) Moreover, the company hereby declares that: the wooden pellet boiler stoves MILLA H 12 comply with the requirements in the following European Directives: 2014/35/UE - Low Voltage Directive...
  • Page 3: Introduction And Readers Of This Manual

    European regulations. For the Commissioning is required for activation of the Edilkamin installation, and for anything not specifically indicated in the manufacturer warranty. The warranty is only valid in the manual, observe local regulations.
  • Page 4: Safety Information

    DO NOT PLACE LAUNDRY ON Edilkamin nor the retailer are liable for damage resulting from incorrect THE APPLIANCE. DO NOT PLACE DRYING RACKS WITHIN THE SAFETY installation or maintenance. CLEARANCE. Keep flammable fluids Safety risks may be caused by: away from the appliance.
  • Page 5: Dimensions

    DIMENSIONS MILLA H (cm) 16,6 14,4 Ø 8 cm Ø 4 cm smoke outlet combustion air loading G 1/2” M return G 3/4” M delivery G 3/4” M USER/INSTALLER...
  • Page 6: Technical Data

    TECHNICAL DATA TECHNICAL DATA as per EN 14785 MILLA H 12 Nominal power Reduced power Available power 12,4 Heat output to water 10,2 Efficiency 93,0 93,2 CO emissions at 13% O 0,004 0,009 Smoke temperature °C Fuel consumption kg/h Tank capacity...
  • Page 7: Unpacking

    UNPACKING PREPARATION AND UNPACKING The packaging materials are neither toxic nor noxious and do not require special disposal. The user is responsible for storing, disposing of and recycling them in a regulatory fashion. Always move the stove vertically with suitable equipment and in compliance with safety regulations.
  • Page 8 UNPACKING Package materials such as plastic andfilms my be dangerous for children. Suffocation hazard. Keep packages away from children. DO NOT TRY TO REMOVE THE PRODUCT FROM THE PALLET WITHOUT HAVING OPENED THE COMBUSTION CHAMBER DOOR AND UNDONE THE SCREWS WHICH FIX IT TO THE PALLET TO REMOVE THE STOVE FROM THE PALLET Loosen the screws that secure the product to the pallet.
  • Page 9: Water Circuit Installation

    (*) as indicated in the figure of the system. below. Edilkamin proposes an analogue pressure • The hot water exiting from the output of the stove gauge as optional.
  • Page 10 WATER CIRCUIT INSTALLATION The pellet boiler stove is equipped with: - Hydraulic kit with closed expansion tank, - circulator pump - pressure relief valve. PIPE KIT Measurements in mm MANDATA RISCALDAMENTO RITORNO RISCALDAMENTO ACQUA FREDDA HEATING DELIVERY HEATING RETURN COLD WATER (3/4") (3/4") (1/2")
  • Page 11 WATER CIRCUIT INSTALLATION PUMP SPECIFICATIONS The pump has no adjustment devices. Adjustments are made via the micro processor on the boiler stove: “begin” at the lowest speed and make adjustments based on the progression of the water temperature. Below is the descriptions for the LED signals. LEDS MEANING CAUSE...
  • Page 12: Installation

    INSTALLATION EATING CONFIGURATION INSTALLER...
  • Page 13 INSTALLATION BOILER CONFIGURATION INSTALLER...
  • Page 14 INSTALLATION PUFFER CONFIGURATION INSTALLER...
  • Page 15 INSTALLATION TERMINAL BOARD One terminal board (10 poles) is low voltage and the other (6 poles) is high voltage. You can find some connection examples below. Poles are identified with a number on the product as described below Low voltage terminal board N°...
  • Page 16 • The appliance may not be installed in a bedroom, Contact the authorised Edilkamin Technical Assistance bathroom or in the same room as other equipment Centre. which draws air for combustion from the room itself, or in any area with an explosive atmosphere.
  • Page 17 INSTALLATION FLUE SYSTEM(SMOKE DUCT, FLUE AND THE SMOKE DUCT CHIMNEY POT) Further to the general prescriptions for the smoke duct This chapter has been drawn up pursuant to European and flue, the smoke duct: standards EN 13384, EN 1443, EN 1856 and EN 1457. •...
  • Page 18 INSTALLATION THE FLUE: AIR INTAKE FOR COMBUSTION Further to the general prescriptions, the flue must In general, we suggest two ways to ensure a proper • only be used to discharge smoke flow of combustion air. Air must come from the outside* •...
  • Page 19 The electrical system must be compliant; check the operation of the earth in particular. Edilkamin is not responsible for malfunctions resulting from an improperly earthed system. The power line must be of adequate section for the power of the appliance.
  • Page 20: Lining

    LINING Fig. 1 fig. 1 - Put the side (A) in this position - Use the screws to fix it - repeat for the other side Then, put the top. INSTALLER...
  • Page 21: Introduction About Use

    INTRODUCTION ABOUT USE FIRST IGNITION (COMMISSIONING) LOADING THE PELLETS INTO THE TANK. PHASES To access the tank, open the lid. • Make sure you have read and understood this manual. When the boiler stove is hot, DO NOT • Remove all flammable materials from the appliance MAKE CONTACT between the pellet bag (manuals, labels, etc.).
  • Page 22: Display

    SPECIFICA TECN DESCRIPTION OF THE DISPLAY INTERFACE 6.4 Schermata di ON The sole interface is the display. The views display the functions and are described in the following sections ON/OFF Il display è diviso in 2 parti da una linea. Sopra la linea c’ BUTTONS SPECIFICA TE SPECIFICA T...
  • Page 23 principale. Nella barra di stato sono presenti i simboli delle richieste calore (RISC e SANITARIO), Il display è diviso in 2 parti da una linea. Sopra la linea c’è la barra di stato, sotto l’area SPECIFICA T l’eventuale attivazione della pompa e l’ora. principale.
  • Page 24: Operational Logic

    The activation of the anti-freeze (both level 1 and level TempCald < Ton_Pompa. 2) is indicated by the symbol “frost” on the display. • due to Black Out L’attivazione della funzione antigelo (sia live Il contenuto di questo documento è proprietà di EdilKamin S.p.A. USER...
  • Page 25 OPERATIONAL LOGIC From the OFF screen, press and hold the ON/OFF button to go to the ON screen. ON MODE The product is “active” and can produce heat. The product can be on/in ignition. The display shows • the current time •...
  • Page 26 OPERATIONAL LOGIC ON MODE with STAND BY While in stand-by mode, and ON, the In ON mode with STAND BY (the product is “active” product turns on only if there is a heat but with stand by function enabled) the product turns request.
  • Page 27: Commands And Menu

    COMMANDS AND MENU Nome: Nome: Rev: SPECIFICA TECNICA Rev: Data: SPECIFICA TECNICA Data: Pagina Pagina From the display, you can: Switching on and off will take a few minutes, • Switch from OFF to ON modes, by during which the flame must appear or go pressing and holding the ON/OFF button off.
  • Page 28: Stand By

    8 Menù Premendo il tasto “M” si accede al Menù. SPECIFICA T STAND BY MENU 8 Menù Menu Press the “M” button to display the menu. Premendo il tasto “M” si accede al Menù. When the menu displays, the buttons have the Pressione tasto “+”...
  • Page 29: Crono

    SPECIFICA T CRONO MENU Crono Il radiocomando consente la programmazione ora passo di 30’. Crono - PROGRAM(figures on the side) When the Crono function is active, the user sets a temperature setpoint and a time zone for which that PROGRAM setpoint is specified.
  • Page 30 SPECIFICA TE SPECIFICA T Crono Crono CRONO MENU Il radiocomando consente la programmazione orar Il radiocomando consente la programmazione orar passo di 30’. passo di 30’. Setting of the time periods, “SET” on the display (figure on the side) Se scelgo la voce Imposta From Crono, press the “OK”...
  • Page 31 SPECIFICA CRONO MENU Visualizza: Display the Crono function, “SHOW” (figures on the side) From Crono, press the “OK” button to enter the “DISPLAY” function. The buttons have the following functions: SHOW “+”: to scroll through the days ahead “-” : to scroll through the days back “OK”: return to the previous menu “M”: return to the previous menu ON/OFF: return to the main screen.
  • Page 32 Temperature: Permette l’impostazione della temperatura caldaia ed dell’accumulo. Se è attivata la sonda esterna, permet TEMPERATURE MENU SPECIFICA TE climatica al posto della temperatura caldaia. SPECIFICA TEC SPECIFICA TE SPECIFICA TE Setting water Temperature (“TEMPERATURE” on the display) Temperature: Allows you to set the boiler temperature and the Temperature: Temperature: Permette l’impostazione della temperatura caldaia...
  • Page 33: Many

    Ventilazione: VARIOUS MENUS Permette di impostare la velocità del ventilatore tra Fan setting (“VENTILATION” on the display) To access the function from the main menu (as indicated in the Menu section above), press the M button. Scroll using the +/- buttons and select the function by pressing the “OK”...
  • Page 34 VARIOUS MENUS Beep Allows you to enable/disable the beep. To access the function from the main menu (as indicated in the Menu section above), press the M button. Scroll using the +/- buttons and select the function by pressing OK. Use the “+/-”...
  • Page 35: Maintenance

    MAINTENANCE Disconnect the product from the power supply. Failure to service the product properly will prevent it from working properly. Any problems due to failure in servicing the stove will void the warranty. DAILY MAINTENANCE Do not dump the cleaning residue into the pellet tank. These operations must be done with the product off, Once it is refitted, make sure that the ash tray is properly cold and preferably disconnected from the mains.
  • Page 36 MAINTENANCE WEEKLY MAINTENANCE When the product is off and cold, after having activated the cleaning brush as in routine maintenance, you should vacuum the inspection plate under the combustion chamber (*) To access: • Open the door using the cold handle (removable handle) •...
  • Page 37 You should clean the chimney system at least once a Using non-original spare parts may damage the year (check local regulations for details). appliance and relieves Edilkamin of all liability for damage that may arise from doing this. If you fail to regularly clean and inspect the system, Do not make unauthorised modifications.
  • Page 38: Troubleshooting

    TROUBLESHOOTING If problems occur, the product shuts itself off automatically. The display will show the reason (see below). Do not disconnect from the power supply. To start the product up again, allow the shut-down procedure to complete, then press the ON/OFF button.
  • Page 39 TROUBLESHOOTING MESSAGE PROBLEM SOLUTION • Check the type of pellet (contact the technician if in Shut-down due to exceeding doubt) maximum smoke temperature • contact the technician Switching OFF due to excessive • see HO7 overheating of the product Shut down due to gear motor •...
  • Page 40 If the water in the boiler stove reaches a temperature of 85°C, the boiling stove shuts down without switching to alarm mode. The text STBY appears on the display next to the room temperature. The product is working, but it must be serviced by an authorised Edilkamin technician. MAINTENANCE (SIGNAL THAT DOES NOT CAUSE SHUT-DOWN) A wrench symbol is shown on the display after 2000 hours of operation.
  • Page 44 *942028-GB* w w w . e d i l k a m i n . c o m code 942028-GB 03.19/A...