the product operates with the PossIbLe MoDes (described below):
off MoDe
on MoDe
stAnD by MoDe
ALARM MoDe
off MoDe
The product is "disabled" and does not produce heat. The product may turn on only for the anti-freeze function
(described on this page). You can set the product to the OFF mode by pressing the ON/OFF button on the display.
Also an external contact (crono, phone dialler) may switch the boiler stove to the OFF mode.
Pressing the +/- keys has no effect. Pressing the M key displays the Menus.
The display shows the current time, room temperature and the status in relation to which the product is OFF.
The product can be in the OFF mode in these cases:
• due to manual operation of the user (with probe)
• due to manual operation of the user (with thermostat)
34
• due to crono
• due to Black Out
La funzione Antigelo si attiva esclusivame
funzione antigelo è attiva (default "Non attiv
sonda di caldaia e della temperatura letta d

oPeRAtIonAL LoGIc

La temperatura Sonda Esterna viene filtrata
L'antigelo funziona anche se è presente la s
La funzione preserva esclusivamente il circu
La condizione di attivazione dell'antigelo Liv
Le condizioni di attivazione dell'antigelo Live
Azioni
ANTI-FREEZE (selectable from the Menu
only by the Technical Assistance Centre
during commissioning)
Can only be activated from OFF and STAND-BY
modes.
The function preserves only the heating circuit, not the
domestic hot water circuit.
The anti-freeze has two levels:
• level 1: pump on
• level 2: pump and boiler stove on; it is activated
by the anti-freeze mode "level 1" if the probe
temperature reads a temperature which is below
the Anti-freeze Setpoint.
The activation of the anti-freeze (both level 1 and level
2) is indicated by the symbol "frost" on the display.
L'attivazione della funzione antigelo (sia live
Il contenuto di questo documento è proprietà di EdilKamin S.p.A.
UseR
3.4 Antigelo
• TempCald < SetAntigelo + 3°C
TempEsterna < SetAntigelo – 3°C
per almeno 200 secondi
• Dallo stato antigelo Livello 1
• TempCald < SetAntigelo
per almeno 300 secondi
ANTIGELO LIVELLO 1:
Viene attivata la pompa PWM al m
comando pari a 10' ON e 120' OFF
Se la valvola 3 vie è in sanitario si po
Se la (TempCald > SetAntigelo + 4°
ciclo di comando delle pompe term
le pompe vengono spente e si esce
Se TempCald < SetAntigelo si entra
ANTIGELO LIVELLO 2 (procedura di acc
Se la valvola 3 vie è in sanitario si po
La stufa viene accesa secondo la pr
La stufa rimane in Stabilizzazione
Ton_Pompa, a questo punto va in S
TempCald < Ton_Pompa.