EdilKamin KIRA H 18 Installation, Use And Maintenance Manual page 46

Pellet boiler stove
Table of Contents

Advertisement

WeeKLy MAIntenAnce
When the product is off and cold, after having activated the cleaning brush as in routine maintenance, you should
vacuum the inspection plate under the combustion chamber (*)
To do so, remove the deflector (D) which is only resting on it.
Put back the deflector after cleaning.
seAsonAL MAIntenAnce
(to
be
carried
46
assistance centre)
This consists of cleaning the stove inside and out.
If the product is used intensively, we
recommend cleaning the smoke duct and
flue every 3 months.
You should clean the chimney system at least once a
year (check local regulations for details).
If you fail to regularly clean and inspect the system,
there is an increased risk of the chimney pot catching
fire.
We recommend against using compressed air to clean
the combustion air inlet.
MAIntenAnce
c
D
out
by
the
technical
UseR/InstALLeR
D
sUMMeR sHUtDoWn
During the period of disuse, keep the stoves doors,
hatches and lids closed.
We recommend emptying out the pellet tank. Place the
package of dessicating salts inside the combustion
chamber.
sPARe PARts
for any spare parts, contact your retailer or technician.
Using non-original spare parts may damage the
appliance and relieves Edilkamin of all liability for
damage that may arise from doing this.
Do not make unauthorised modifications.
DIsPosAL
At the end of its service life, dispose of the product as
required by regulations.
*