EdilKamin KIRA H 18 Installation, Use And Maintenance Manual page 13

Pellet boiler stove
Table of Contents

Advertisement

oPtIonAL HyDRAULIc KIt All kits are supplied with instructions for their connection to the boiler stove
Edilkamin technicians have a paper template suitable for each product. Make sure the correct one is used for the
product being installed.
Position the template so as to be flush with the floor and aligned with the left side of the maximum space occupied
by the boiler stove.
Be sure to respect the correct installation clearances away from flammable materials and for maintenance operations.
exAMPLes of HyDRAULIc InstALLAtIon
N.B.: These diagrams are for guidance only, the correct execution is the responsibility of the
plumber and the parameters must be set by the Technical Assistance Centre during first
ignition (commissioning).
These pages only include indications of possible installations and uses which must be
defined together with the installer and the Technical Assistance Centre during first ignition.
HeAtInG onLy
The combinable Kits are:
• Pipe kit
• Kit R
• Kit R2
The demand for heating can be made:
by the room temperature probe (if the read temperature falls 1°C below the set temperature).
The demand for heating is represented by a radiator on the display.
HeAtInG AnD InstAnt DoMestIc Hot WAteR
The combinable Kits are:
• Pipe kit
• Kit R
• Kit RW
• Kit R2
The demand for heating can be made:
by the room temperature probe (if the read temperature falls 1°C below the set temperature);
by the flow switch, following the opening of the hot water tap.
The demand for heating is represented by a radiator or by a tap on the display.
HeAtInG AnD boILeR foR DoMestIc Hot WAteR
The Kits combinable with the boiler are:
• Pipe kit
• Kit R
The demand for heating can be made:
by the room temperature probe (if the read temperature falls 1°C below the set temperature);
by the boiler thermostat/probe demanding domestic hot water.
If there is a request for domestic hot water, the pump of the boiler stove turns on if the temperature of the boiler
stove is 5°C above the temperature of the boiler; if this happens the three-way valve deviates to the domestic water
supply. The distribution pump is off.
coMbInAtIon WItH AccUMULAtoR tAnK
The Kits combinable with the accumulator are:
• Pipe kit
• Kit R
The accumulation probe must be set as accumulator tank probe
The demand for heating can be made:
by the thermostat/probe of the accumulator tank.
The pump of the boiler stove ensures the heat transfer from the boiler stove to the accumulator tank.
The (secondary) booster pump provides heat transfer from the accumulator tank to the system.
The timer programming on the display applies to the (secondary) booster pump.
WAteR cIRcUIt InstALLAtIon
InstALLeR
13