Mechanical installation
3.2 Cabinet panel mounting (frame sizes A ... D)
3.2
Cabinet panel mounting (frame sizes A ... D)
You can mount the inverter directly on the surface of the cabinet panel.
An additional mounting method is also available for different frame sizes. For more details,
refer to the following section:
● Push-through mounting (frame sizes B ... D) (Page 18)
Outline dimensions and drill patterns
Dimensions (mm)
Frame size A
Height of frame size A with fan
1)
Frame size B
16
Drill pattern (mm)
Fixings:
4 x M4 screws
4 x M4 nuts
4 x M4 washers
Tightening torque: 1.8 Nm ± 10%
Fixings:
4 x M4 screws
4 x M4 nuts
4 x M4 washers
Tightening torque: 1.8 Nm ± 10%
SINAMICS V20 Inverter