Parameter list
7.2 Parameter list
Parameter
Function
P2186[0...2]
Lower torque threshold 1
[Nm]
Lower limit threshold value 1 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2187[0...2]
Upper torque threshold 2
[Nm]
Upper limit threshold value 2 for comparing actual torque.
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
See P2181 for calculated default value.
Note:
See P2185
P2188[0...2]
Lower torque threshold 2
[Nm]
Lower limit threshold value 2 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2189[0...2]
Upper torque threshold 3
[Nm]
Upper limit threshold value 3 for comparing actual torque.
Dependency:
This parameter is influenced by automatic calculations defined by P0340.
See P2181 for calculated default value.
Note:
See P2185
P2190[0...2]
Lower torque threshold 3
[Nm]
Lower limit threshold value 3 for comparing actual torque.
Dependency:
See P2181 for calculated default value.
P2192[0...2]
Time delay for belt
failure [s]
P2192 defines a delay before warning / trip becomes active.
- It is used to eliminate events caused by transient conditions.
- It is used for both methods of fault detection.
r2197.0...12
CO / BO: Monitoring
word 1
Monitoring word 1 which indicates the state of monitor functions. Each bit represents one monitor function.
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
198
Range
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0.0 -
99999.0
0 - 65
-
Signal name
|f_act| <= P1080 (f_min)
|f_act| <= P2155 (f_1)
|f_act| > P2155 (f_1)
f_act >= zero
f_act >= setp. (f_set)
|f_act| <= P2167 (f_off)
|f_act| >= P1082 (f_max)
f_act == setp. (f_set)
Act. current |r0027| >= P2170
Act. unfilt. Vdc < P2172
Act. unfilt. Vdc > P2172
Load missing
|f_act| > P1082 with delay
Factory
Can be
default
changed
0.0
U, T
Value in
U, T
r0333
0.0
U, T
Value in
U, T
r0333
0.0
U, T
10
U, T
-
-
Scaling
Data
set
-
DDS
-
DDS
-
DDS
-
DDS
-
DDS
-
DDS
-
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
Data
Acc.
type
Level
Float
3
Float
3
Float
3
Float
3
Float
3
Float
3
U16
3
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No