Parameter list
7.2 Parameter list
Parameter
Function
Dependency:
P1060 and P1061 set up and down ramp times respectively for jogging. Rounding times (P1130 - P1133),
rounding type (P1134) and P2167 will also have influence on the JOG ramp.
P1059[0...2]
JOG frequency left [Hz]
While JOG left is selected, this parameter determines the frequency at which the inverter will run.
Dependency:
P1060 and P1061 set up and down ramp times respectively for jogging.
P1060[0...2]
JOG ramp-up time [s]
Sets jog ramp-up time. This is the time used while jogging is active.
Dependency:
See also P3350, P3353.
Notice:
Ramp times will be used as follows:
P1060 / P1061 : JOG mode is active
P1120 / P1121 : Normal mode (ON / OFF) is active
P1060 / P1061 : Normal mode (ON / OFF) and P1124 is active
The rounding of P1130 - P1133 also applies to the JOG ramping.
Note:
If the SuperTorque function is enabled, the inverter will initially ramp using the value in P3353.
P1061[0...2]
JOG ramp-down time [s]
Sets ramp-down time. This is the time used while jogging is active.
Dependency:
See also P3350, P3353.
Note:
See P1060
P1070[0...2]
CI: Main setpoint
Defines source of main setpoint.
P1071[0...2]
CI: Main setpoint scaling
Defines source of the main setpoint scaling.
P1074[0...2]
BI: Disable additional
setpoint
Disables additional setpoint.
P1075[0...2]
CI: Additional setpoint
Defines source of the additional setpoint (to be added to main setpoint).
P1076[0...2]
CI: Additional setpoint
scaling
Defines source of scaling for additional setpoint (to be added to main setpoint).
r1078
CO: Total frequency
setpoint [Hz]
Displays sum of main and additional setpoints.
r1079
CO: Selected frequency
setpoint [Hz]
Displays selected frequency setpoint. Following frequency setpoints are displayed:
r1078 Total frequency setpoint
P1058 JOG frequency right
P1059 JOG frequency left
Dependency:
P1055 (BI: Enable JOG right) or P1056 (BI: Enable JOG left) define command source of JOG right or JOG
left respectively.
164
Range
Factory
default
0.00 -
5.00
599.00
0.00 -
10.00
650.00
0.00 -
10.00
650.00
-
1050[0]
-
1
-
0
-
0
-
[0] 1 [1] 0
[2] 1
-
-
-
-
Can be
Scaling
changed
U, T
-
U, T
-
U, T
-
T
-
T
4000H
U, T
-
T
-
T
4000H
-
-
-
-
Operating Instructions, 07/2012, A5E03728167
Data
Data
Acc.
set
type
Level
DDS
Float
2
DDS
Float
2
DDS
Float
2
CDS
U32 /
3
I32
CDS
U32 /
3
I16
CDS
U32 /
3
Bin
CDS
U32 /
3
I32
CDS
U32 /
3
I16
-
Float
3
-
Float
3
SINAMICS V20 Inverter