Siemens SINAMICS V20 Series Operating Instructions Manual page 60

Hide thumbs Also See for SINAMICS V20 Series:
Table of Contents

Advertisement

Commissioning
5.6 Function commissioning
● Motor brake controls (holding brake, DC brake, compound brake and dynamic brake)
● DC-link voltage control (P0210, P1240 ... P1257, see also "Setting the Vdc controller
● I
● Continuous boost, acceleration boost and starting boost level control (P1310 ... P1316,
● Programmable V/f coordinates (P1320 ... P1333)
● Slip compensation (P1334 ... P1338)
● Economy mode (see "Running the inverter in economy mode (Page 89)".)
● Super torque mode (see "Starting the motor in super torque mode (Page 83)".)
● Hammer start mode (see "Starting the motor in hammer start mode (Page 85) ".)
● Blockage clearing mode (see "Starting the motor in blockage clearing mode (Page 87)")
● Adjustable PWM modulation (P1800 ... P1803)
● USS / MODBUS communication on RS485 (P2010 ... P2037)
● Cavitation protection (P2360 ... P2362, see also "Running the inverter in cavitation
● Sleep (hibernation) mode (P2365 ... P2367, see also "Running the inverter in sleep mode
● Motor staging (P2370 ... P2380, see also "Running the inverter in motor staging mode
● PID controller (P2200 ... P2355, see also "Setting the PID controller (Page 67)".)
● Motor blocking, load missing, belt failure detection (P2177 ... r2198, see also "Setting the
● Free function blocks (FFBs) (P2800 ... P2890, see also "Setting the free function blocks
● Frost protection (P3852, P3853, see also "Running the inverter in frost protection mode
● Condensation protection (P3854, see also "Running the inverter in condensation
● Wobble function (P2940 ... r2955, see also "Setting the wobble generator (Page 97)".)
● BICO function (r3978)
60
(P1212 ... P1237, see also "Setting the braking function (Page 69)".)
(Page 81)".)
control (P1340 ... P1346, see also "Setting the Imax controller (Page 79)".)
max
see also "Setting the voltage boost (Page 64)".)
protection mode (Page 101)".)
(Page 96)".)
(Page 98)".)
load torque monitoring function (Page 82)".)
(FFBs) (Page 91)".)
(Page 94)".)
protection mode (Page 95)".)
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents