Parameter
Function
P1042[0...2]
CI: MOP auto setpoint
Sets the signal source for the setpoint of the motorized potentiometer if automatic mode P1041 is selected.
Notice:
Refer to: P1041
P1043[0...2]
BI: MOP accept
rampgenerator setpoint
Sets the signal source for the setting command to accept the setting value for the motorized potentiometer.
The value becomes effective for a 0 / 1 edge of the setting command.
Notice:
Refer to: P1044
P1044[0...2]
CI: MOP rampgenerator
setpoint
Sets the signal source for the setpoint value for the MOP. The value becomes effective for a 0 / 1 edge of
the setting command.
Notice:
Refer to: P1043
r1045
CO: MOP input
frequency of the RFG
[Hz]
Displays the motorized potentiometer setpoint before it passed the MOP RFG.
P1047[0...2]
MOP ramp-up time of
the RFG [s]
Sets the ramp-up time for the internal MOP ramp-function generator. The setpoint is changed from zero up
to limit defined in P1082 within this time.
Notice:
Refer to: P1048, P1082
P1048[0...2]
MOP ramp-down time of
the RFG [s]
Sets the ramp-down time for the internal MOP ramp-function generator. The setpoint is changed from limit
defined in P1082 down to zero within this time.
Notice:
Refer to: P1047, P1082
r1050
CO: Actual output freq.
of the MOP [Hz]
Displays output frequency of motor potentiometer setpoint.
P1055[0...2]
BI: Enable JOG right
Defines source of JOG right when P0719 = 0 (Auto selection of command / setpoint source).
P1056[0...2]
BI: Enable JOG left
Defines source of JOG left when P0719 = 0 (Auto selection of command / setpoint source).
P1057
JOG enable
While JOG enable is '0' Jogging (P1056 and P1055) is disabled. When '1' Jogging is enabled.
P1058[0...2]
JOG frequency [Hz]
Jogging increases the motor speed by small amounts. The JOG mode allows the operator to perform a
specific number of revolutions and position the rotor manually. In JOG mode, the RUN button on the
operator panel for jogging uses a non-latching switch on one of the digital inputs to control the motor
speed. While jogging, P1058 determines the frequency at which the inverter will run. The motor speed is
increased as long as 'JOG left' or 'JOG right' are selected and until the left or right JOG frequency is
reached.
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
Range
Factory
default
-
0
-
0
-
0
-
-
0.00 -
10.00
1000.00
0.00 -
10.00
1000.0
-
-
-
19.8
-
0
0000 bin -
0001 bin
0001 bin
0.00 -
5.00
599.00
Can be
Scaling
changed
T
-
T
-
T
-
-
-
U, T
-
U, T
-
-
-
T
-
T
-
T
-
U, T
-
Parameter list
7.2 Parameter list
Data
Data
Acc.
set
type
Level
CDS
U32 /
3
I32
CDS
U32 /
3
Bin
CDS
U32 /
3
I32
-
Float
3
DDS
Float
2
DDS
Float
2
-
Float
2
CDS
U32 /
3
Bin
CDS
U32 /
3
Bin
-
U16
3
DDS
Float
2
163

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents