Options and spare parts
B.2 Spare parts - replacement fans
B.1.9

Memory card

Functionality
The memory card can be used on the Parameter Loader or the BOP Interface Module and
allows you to upload / download parameter sets to / from the inverter. For detailed use of the
memory card, refer to Appendices "Parameter Loader (Page 247)" and "External BOP and
BOP Interface Module (Page 251)".
Order number
The MMC / SD cards with the following order numbers are recommended.
● MMC card: 6SL3254-0AM00-0AA0
● SD card: 6ES7954-8LB01-0AA0
B.1.10

User documentation

Operating Instructions (Chinese version)
Order number: 6SL3298-0AV02-0FP0
B.2

Spare parts - replacement fans

Order numbers
Replacement fan for frame size A: 6SL3200-0UF01-0AA0
Replacement fan for frame size B: 6SL3200-0UF02-0AA0
Replacement fan for frame size C: 6SL3200-0UF03-0AA0
Replacement fan for frame size D: 6SL3200-0UF04-0AA0
Replacing fans
Proceed as illustrated below to remove the fan from the inverter. To re-assemble the fan,
proceed in reverse order. When re-assembling the fan, make sure that the arrow symbol ("A"
in the illustration) on the fan points to the inverter rather than the fan housing, the position for
the fan cable exit point ("B") as well as the mounting orientation and position of the cable
connector ("C") are sufficient for connecting the fan cable to the inverter.