REMARKS ON INSTALLATION
Note that:
installation must be carried out by authorised
technical personnel;
The appliance must be installed and operated
in compliance with local and national law and
European regulations. The applicable Italian
standard is UNI 10683;
If installed in a condominium, the appliance must
be approved by the administrator.
We give some general instructions below, however
these do not obviate the need to comply with local
regulations and do not imply any liability as regards
the installer's work.
Checking the suitability of the installation
space
The room must have a volume of at least 30 m
The floor must be able to bear the weight of the
product and its accessories.
Level the product (the product is provided with
adjustable feet).
The appliance may not be installed in a bedroom,
bathroom or in the same room as other equipment
which draws air for combustion from the room
itself, or in any area with an explosive atmosphere.
Any extraction fans operating in the same room or
area as the product, may affect its draw.
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas fired
products.

INSTALLATION

NOTE
To load the pellets and perform maintenance, there must
be at least two doors on the left-hand and right-hand
sides (170x55 cm).
See following page.
You can load from either the right or left. You can decide
during the installation phase.
Warning:
if the fume outlet points upwards, you can only load from
the right-hand side.
.
3
INSTALLER
13