The display will show:
the symbols of the heat request (radiator, tap,
pump activation);
the current time;
the room temperature*;
the operating power of the product (from 1
upwards), as represented by the flame symbols;
the fan speed, as represented by the filled blades
symbol (if absent, the fan is off).
Example of domestic hot water request.
Room temperature
Room temperature
setting
Power indication
Tap
If you are using a room thermostat instead of the room
probe provided as standard, the display will appear as
below. The heat demand is indicated by the radiator
symbol.
USER INSTRUCTIONS
Current time
* The product is programmed by default with a delta of +/- 1 °C to
optimise comfort.
The technician can change this setting during commissioning to suit
the needs of the application.
The display shows the temperature rounded down. This means that
20.1°C and 20.9°C are indicated as "20°".
E.g., with the room temperature set to 20° C, the product will enter
modulation mode/switch off when a temperature of 21° C is reached
and will switch on again below 19° C.