In the list of parts, a code number is given and this must be quoted if a request for spare parts is made. Declaration of conformity The undersigned EDILKAMIN S.p.a. with head office headquarters at Via Vincenzo Monti 47 - 20123 Milan - Italy - VAT IT00192220192 Declares under its own responsability as follows:...
Hot sanitary water production (kit 1-3-n3-n3bis-6) l/min The fireplace must be installed with an open tank (EXCEPT FOR IDRO 50/CS). Heating capacity The water of the radiator circuit warms up, circulates in the heat exchanger pipe (4) and the hollow space (A) and...
Page 4
GENERAL SAFETY REGULATIONS • THE THERMO FIREPLACE MUST NEVER (VALID ONLY FOR IDRO 50/CS) FUNCTION WITHOUT WATER IN THE SYSTEM. • THE THERMO FIREPLACE CAN BE DAMAGED IF IT IS IGNITED WITH NO WATER IN THE SYSTEM. • The thermo fireplace is designed to heat water by means of wood combustion in the hearth.
Page 5
(water treatment in domestic heating systems). CLOSED TANK additional regulations to those specified above (VALID ONLY FOR IDRO 50/CS) - Be careful not to exceed 1.5 bar when filling the system. - All the vents of the radiators must be ope-...
INSTALLATION INSTRUCTIONS External air inlet (optional) Chimney flues and chimneypot Important advice regarding installation An external connection with a 10 cm The thermo fireplace smoke outlet has a cir- cular crosssection so that stainless steel pipes diameter crosssection throughout Other than that described in this documen- (refer to the technical table) is absolu- can be used.
INSTALLATION AND USE INSTRUCTIONS Transporting the fireplace on the contrary, there must be an appropriate - Close the door distance of at least 1 cm to allow the air to In order to facilitate transportation, the firepla- flow, preventing heat accumulation. - Adjust the combustion setting via the damper ce can be made lighter by removing the follo- control at the front.
Page 8
SYSTEM FOR AN OPEN TANK INSTALLATION KIT 1 USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE WITH HOT SANITARY WATER PRODUCTION ACS: Hot Sanitary Water Cold Water 3-way Solenoid Valve Flow Switch System Flow KIT 1 Normally Open Normally Closed Pump (circulator) Radiators...
Page 9
SYSTEM FOR AN OPEN TANK INSTALLATION KIT 2 USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE THAT DOES NOT PRODUCE HOT SANITARY WATER BUT HAS A WALL MOUNTED BOILER Cold Water Wall Mounted Boiler KIT 2 System Flow Pump (circulator) Radiators Electronic Regulator...
Page 10
SYSTEM FOR AN OPEN TANK INSTALLATION KIT 3 USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRODUCTION AND A WALL MOUNTED BOILER ACS: Hot Sanitary Water Cold Water Wall Mounted Boiler 3-way Solenoid Valve Flow Switch System Flow KIT 3...
Page 11
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the fireplace. Components KIT N3 Heating system return G 3/4” EDILKAMIN generator flow G 3/4” EDILKAMIN generator return G 3/4” Heating system flow G 3/4” Cold sanitary water inlet G 1/2”...
Page 12
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the fireplace. Components KIT N3 BIS Heating system return G 3/4” EDILKAMIN generator flow G 3/4” EDILKAMIN generator return G 3/4” 11 11 11 11 Heating system flow G 3/4”...
Page 13
SYSTEM FOR AN OPEN/CLOSED TANK INSTALLATION IDROKIT USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE THAT PRODUCES AND STORES HOT SANITARY WATER AND HAS A WALL MOUNTED BOILER ACS: Hot Sanitary Water IDROKIT Cold Water Water Mains Supply Filling/Top-Up Section Electronic Panel 3-way Solenoid Valve...
Page 14
SYSTEM FOR A CLOSED TANKINSTALLATION (VALID ONLY FOR IDRO 50/CS) KIT 5 USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE - ONLY HEATING safety valve connection KIT 5 Water Mains Supply Filling/Top-Up Section 3-way Solenoid Valve Normally Open...
Page 15
SYSTEM FOR A CLOSED TANKINSTALLATION (VALID ONLY FOR IDRO 50/CS) KIT 6 USING AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE WITH HOT SANITARY WATER PRODUCTION safety valve connection ACS: Hot Sanitary Water KIT 6 Cold Water Water Mains Supply...
Page 16
ELECTRONIC REGULATOR (KIT 1-2-3-5-6) The electric control regulator allows you to monitor the operating electronic regulator conditions and is equipped with: - MAN-OFF-AUTO selector (S) - temperature scale (ST) IMPORTANT ADVICE REGARDING THE INSTALLATION - acoustic alarm (AA) - 3-way valve opening setting (R) (KIT1-3) The connections, commissioning and verification of proper operation - circulators operation setting (R) (KIT2) of the fireplace must be carried out by qualified personnel, who can...
Page 17
The electronic regulator and the plate exchanger are included in the installation KITS Roaster (supplied as optional extras) Exchanger 3-way Idro 50-70 cod. 234560 code 627780 Idro 100 cod. 236710...