Installation (Fume Discharge, Air Intake) - EdilKamin PELLKAMIN 12 Installation, Use And Maintenance Manual

Pellet fireplace
Hide thumbs Also See for PELLKAMIN 12:
Table of Contents

Advertisement

SUMMARY INSTALLATION CHECKS
For details, refer to the respective pages of this manual.
Element to be checked
Suitability of the room
Volume of room
Load bearing capacity of the floor/base
Safety clearance from flammable materials
Air intake
Flue
Power socket
Hole for ventilation air
Ducting for ventilation air *
12
INSTALLATION IN AN EXISTING FIREBOX
In addition to the above, check, in particular, fort
If you wish to install the appliance in an existing firebox, you must bear the following in mind, in addition to observ-
ing all regulations and the instructions in this manual:
there must be sufficient clearance around the Pellkamin
the possibility of installing the appliance perfectly level on the base *
there must be room for the fan kit and loading trapdoor
the existing cladding must be accessible for installing and, in particular, for checking the fan kit*. For mainte-
nance purposes, the technicians are able to slide the Pellkamin out on its rails.
*if provided for in the version you have purchased
INSTALLATION
What to check
aeration
intended use: do not install in bedrooms, bathroom or fire
hazard areas
> 30 m
3
sufficient to support the product, its accessories and
cladding
see the respective paragraph
existing and suitable
see the respective paragraph
see the respective paragraph
In particular, it must be:
dedicated to a single appliance
made of suitable material;
inspectable
present, with regulatory grounding system
a hole at least 10x10 cm in size, preferably on the side of
the covering
always channel the ventilation warm air (the 6 cm diam-
eter pipe) to the outside