Installation (Fume Discharge, Air Intake) - EdilKamin PELLKAMIN2 12 Directions For Installation, Use And Maintenance

Pellet fireplace
Hide thumbs Also See for PELLKAMIN2 12:
Table of Contents

Advertisement

SUMMARY INSTALLATION CHECKS
SUMMARY INSTALLATION CHECKS
For details, refer to the respective pages of this manual.
For details, refer to the respective pages of this manual.
Element to be checked
Element to be checked
Suitability of the room
Suitability of the room
Volume of room
Volume of room
Load bearing capacity of the floor/base
Load bearing capacity of the floor/base
Safety clearance from flammable materials
Safety clearance from flammable materials
Air intake
Air intake
Flue
Flue
Power socket
Power socket
Hole for ventilation air
Hole for ventilation air
Ducting for ventilation air *
Ducting for ventilation air *
12
INSTALLATION IN AN EXISTING FIREBOX
INSTALLATION IN AN EXISTING FIREBOX
In addition to the above, check, in particular, fort
In addition to the above, check, in particular, fort
If you wish to install the appliance in an existing firebox, you must bear the following in mind, in addition to observ-
If you wish to install the appliance in an existing firebox, you must bear the following in mind, in addition to observ-
ing all regulations and the instructions in this manual:
ing all regulations and the instructions in this manual:
• •
there must be sufficient clearance around the Pellkamin
there must be sufficient clearance around the Pellkamin
• •
the possibility of installing the appliance perfectly level on the base *
the possibility of installing the appliance perfectly level on the base *
• •
there must be room for the fan kit and loading trapdoor
there must be room for the fan kit and loading trapdoor
• •
the existing cladding must be accessible for installing and, in particular, for checking the fan kit*. For mainte-
the existing cladding must be accessible for installing and, in particular, for checking the fan kit*. For mainte-
nance purposes, the technicians are able to slide the Pellkamin out on its rails.
nance purposes, the technicians are able to slide the Pellkamin out on its rails.
*if provided for in the version you have purchased
INSTALLATION
What to check
What to check
• •
aeration
aeration
• •
intended use: do not install in bedrooms, bathroom or fire
intended use: do not install in bedrooms, bathroom or fire
hazard areas
hazard areas
> 30 m
3
sufficient to support the product, its accessories and
cladding
see the respective paragraph
• •
existing and suitable
existing and suitable
see the respective paragraph
see the respective paragraph
In particular, it must be:
dedicated to a single appliance
made of suitable material;
inspectable
present, with regulatory grounding system
• •
a hole at least 10x10 cm in size, preferably on the side of
a hole at least 10x10 cm in size, preferably on the side of
the covering
the covering
always channel the ventilation warm air (the 6 cm diam-
eter pipe) to the outside

Advertisement

Table of Contents
loading

This manual is also suitable for:

809530809550809580809560

Table of Contents